What are the recommended bay
sizes for Forward lifts?
What are the
concrete requirements for
Forward lifts?
What are
the ceiling height requirements for Forward lifts?
What are the
electrical requirements for Forward lifts?
Can my
Forward lift be installed outside?
What amount of
hydraulic fluid is
necessary for my
Forward lift?
What are the recommended bay
sizes for Forward lifts?
|
TWO POST |
|
Forward
Model |
Bay Size
Width |
|
I10 |
14' x
24' |
|
9000B |
15' x
24' |
|
DP10AN |
13' x
24' |
|
DP10A |
14' x
24' |
|
DP10S |
14' x
24' |
|
DP12S |
15' x
24' |
|
DP15S |
15' x
24' |
|
FOUR
POST |
|
Forward
Model |
Bay Size
Width |
|
CR14 |
15' x
26' |
|
OR14 |
15' x
26' |
|
12000LR |
15' x
24' |
|
CR28 |
16' x
33' |
|
40000HDL |
18' x
38' |
|
50000HDL |
18' x
43' |
|
60000HDL |
20' x
48' |
Back to Top
What are the
concrete requirements for
Forward lifts?
|
TWO POST |
Forward
Model |
Anchor
Size |
Min.
Anchor
Embedment |
Min.
Concrete
Thickness |
Min.
Content
PSI |
Min.
Edge
Distance |
Anchor
Torque
Ft-lbs |
|
I10 |
3/4" x 5
1/2" |
3 1/4" |
4 1/4" |
3,000 |
5 11/16" |
150 |
|
9000B |
3/4" x 5
1/2" |
3 1/4" |
4 1/4" |
3,000 |
5 11/16" |
150 |
|
DP10AN |
3/4" x 5
1/2" |
3 1/4" |
4 1/4" |
3,000 |
5 11/16" |
150 |
|
DP10A |
3/4" x 5
1/2" |
3 1/4" |
4 1/4" |
3,000 |
5 11/16" |
150 |
|
DP10S |
3/4" x 5
1/2" |
3 1/4" |
4 1/4" |
3,000 |
5 11/16" |
150 |
|
DP12S |
3/4" x 5
1/2" |
3 1/4" |
6" |
3,000 |
5 11/16" |
150 |
|
DP15S |
3/4" x 5
1/2" |
3 1/4" |
6" |
3,000 |
5 11/16" |
150 |
|
FOUR
POST |
Forward
Model |
Anchor
Size |
Min.
Anchor
Embedment |
Min.
Concrete
Thickness |
Min.
Content
PSI |
Min.
Edge
Distance |
Anchor
Torque
Ft-lbs |
|
CR14 |
3/4" x 5
1/2" |
3 1/4" |
4" |
3,000 |
5" |
150 |
|
OR14 |
3/4" x 5
1/2" |
3 1/4" |
4" |
3,000 |
5" |
150 |
|
12000LR |
3/4" x 5
1/2" |
3 1/4" |
4" |
3,000 |
5 11/16" |
150 |
|
CR28 |
3/4" x 5
1/2" |
3 1/4" |
6" |
3,000 |
5" |
150 |
|
40000HDL |
3/4" x 5
1/2" |
3 1/4" |
6" |
3,000 |
5" |
150 |
|
50000HDL |
3/4" x 5
1/2" |
3 1/4" |
8" |
3,000 |
5" |
150 |
|
60000HDL |
3/4" x 5
1/2" |
3 1/4" |
8" |
3,000 |
5" |
150 |
Back to Top
What are
the ceiling height requirements for Forward lifts?
|
TWO POST |
|
Forward
Model |
Required
Height |
|
I10 |
12' |
|
9000B |
11' |
|
DP10AN |
12' |
|
DP10A |
12' |
|
DP10S |
12' |
|
DP12S |
14' 8" |
|
DP15S |
14' 8" |
|
FOUR
POST |
|
Forward
Model |
Required
Height |
|
CR14 |
12' |
|
OR14 |
12' |
|
12000LR |
12' |
|
CR28 |
16' |
|
40000HDL |
16' |
|
50000HDL |
16' |
|
60000HDL |
16' |
Back to Top
What are the
electrical requirements for Forward lifts?
|
TWO POST |
Forward
Model |
Voltage
Single
Phase |
Amps |
Voltage
Three
Phase |
Amps |
Voltage
Three
Phase |
Amps |
Motor |
|
I10 |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2 HP |
|
9000B |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2 HP |
|
DP10AN |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2 HP |
|
DP10A |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2 HP |
|
DP10S |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2 HP |
|
DP12S |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2 HP |
|
DP15S |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2 HP |
|
FOUR
POST |
Forward
Model |
Voltage
Single
Phase |
Amps |
Voltage
Three
Phase |
Amps |
Voltage
Three
Phase |
Amps |
Motor |
|
CR14 |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2HP |
|
OR14 |
208/230 |
20 |
208/230 |
20 |
400 &
above |
10 |
2HP |
|
12000LR |
208/230 |
25 |
208/230 |
20 |
400 &
above |
10 |
3HP |
|
CR28 |
208/230 |
50 |
208/230 |
25 |
400 &
above |
15 |
4HP |
|
40000HDL |
208/230 |
50 |
208/230 |
25 |
400 &
above |
15 |
2HP x 2 |
|
50000HDL |
208/230 |
50 |
208/230 |
25 |
400 &
above |
15 |
2HP x 2 |
|
60000HDL |
208/230 |
50 |
208/230 |
25 |
400 &
above |
15 |
2HP x 2 |
Back to Top
Can my
Forward lift be installed outside?
Although Forward lifts are
designed for indoor use,
they may be installed
outdoors provided it is
located under a covering
suitable for protection from
direct precipitation.
The power unit motor and
electrical switches are not
suitable for applications
where they may be exposed to
direct precipitation or any
flow of water, such as a
wash bay.
When installing lifts
outside - all electrical
must meet local codes
concerning the application.
This may include, but is not
limited to, Ground Fault
Interrupter (GFI) circuit
breakers and watertight
conduit and fittings.
It should be noted that any
lifts installed outdoors
will require additional
maintenance.
Is
Thermal Overload
Protection needed on
my Forward lift?
As typical with
power units for
vehicle lifts,
Forward power units
do not incorporate
Automatic Thermal
Overloads (ATO) in
the motors. This is
for the following
reasons:
-
The motors on
vehicle lifts
have relatively
short periods of
operation
(usually less
than one minute)
with long
periods of rest
between these
periods of
operations. This
is defined as
Intermittent
Duty according
to the National
Electric Code
(NEC) as
described in
Article 100 -
definitions.
-
According to NEC
Article 430-33,
a motor that is
used as
intermittent
service is
permitted to be
protected
against
overloads by the
branch-circuit
short-circuit
and ground-fault
protection
device.
-
According to NEC
Article 430-33,
a motor cannot
automatically
restart after an
overload trip if
personal injury
can result. An
ATO could cause
an automatic
restart by
masking a failed
switch that has
stayed in the
normally closed
position. This
condition would
allow the motor
to restart after
the ATO reset.
-
With
Intermittent
Duty, the
overcurrent
protection is
more likely to
trip before an
ATO; this
renders the ATO
useless.
Back
to Top
What amount of
hydraulic fluid is
necessary for my
Forward lift?
| TWO POST |
Forward
Model |
Quarts/Gallons
Fluid Required |
Liters Fluid
Required |
| I10 |
10.5 Quarts |
10 Liters |
| 9000B |
10.5 Quarts |
10 Liters |
| DP10AN |
10.5 Quarts |
10 Liters |
| DP10A |
10.5 Quarts |
10 Liters |
| DP10S |
10.5 Quarts |
10 Liters |
| DP12S |
10.5 Quarts |
10 Liters |
| DP15S |
10.5 Quarts |
10 Liters |
| FOUR POST |
Forward
Model |
Quarts/Gallons
Fluid Required |
Liters Fluid
Required |
| CR14 |
11.6 Qts./3 gal. |
11 Liters |
| OR14 |
11.6 Qts./3 gal. |
11 Liters |
| 12000LR |
11.6 Qts./3 gal. |
11 Liters |
| CR28 |
14.8 Qts./3.7 gal. |
14 Liters |
| 40000HDL |
40 Qts./10 gal. |
38 Liters |
| 50000HDL |
40 Qts./10 gal. |
38 Liters |
| 60000HDL |
80 Qts./3 gal. |
76 Liters |
Back to Top
|